R-10 continuous on crawl space walls
In zone 4A, closed crawl space walls need R-13 cavity or R-10 continuous, double the R-5 continuous allowed in zone 3. Closed-cell foam reaches R-10 in a thin layer.
Attic & Crawl Space · Dawson County, GA
NJ Spray Foam LLC insulates attics and crawl spaces in Dawsonville and Dawson County, GA. Mountain and lake homes often sit over damp crawl spaces, and zone 4A rules ask more of crawl space walls than in metro Atlanta.
Attic & Crawl Space Insulation in Dawson County
In zone 4A, closed crawl space walls need R-13 cavity or R-10 continuous, double the R-5 continuous allowed in zone 3. Closed-cell foam reaches R-10 in a thin layer.
Homes on slopes often have partial crawl spaces and walk-out basements. We insulate rim joists and walls where moisture gets in.
Ceilings still need R-38 (R-30 at full depth over the plates) under Georgia's amendments, or R-20 of spray foam at the roof deck.
Insulation and air sealing for the two places Georgia homes lose the most comfort: the attic above and the crawl space below, with spray foam, blown-in insulation or both.
Insulation in new homes and additions is inspected under Georgia's state energy code by Dawson County or the City of Dawsonville, depending on the address. We confirm the office before quoting.
| Location / item | Limit |
|---|---|
| IECC climate zone | 4A (mixed, humid) |
| Attic floor (ceiling) insulation | R-38, or R-30 at full depth over the top plates |
| Spray foam at the roof deck (unvented attic) | R-20 minimum on the trade-off path |
| Wood-frame exterior walls | R-13 |
| Unvented crawl space walls | R-13 cavity or R-10 continuous |
| Unvented attic with fiberglass or cellulose | R-20 plus R-15 rigid foam above the deck |
| Air leakage test on new homes | Under 5 ACH50, by a certified verifier |
| Vented attic (insulate the floor) | Unvented attic (foam the roof deck) | |
|---|---|---|
| Where the insulation goes | On the attic floor | Under the roof deck and gable walls |
| Ducts and air handler | Stay in a hot attic | End up inside the conditioned space |
| Georgia code minimum | R-38 (R-30 at full depth) | R-20 air-impermeable on the trade-off path |
| Best for | Simple attics without HVAC equipment | Attics with ducts, equipment or storage |
We check insulation depth, ductwork, ventilation, moisture and access in the attic and crawl space.
Vented or unvented attic, floor or wall crawl space insulation, and the R-values each option needs in Georgia.
Wet, compressed or contaminated insulation comes out before new work goes in.
Spray foam, blown-in insulation or both, with air sealing at the gaps that leak most.
We confirm depth and coverage and leave the access points clean and closed.
R-13 cavity or R-10 continuous in climate zone 4A, with a sealed Class 1 vapor retarder and a 3-inch termite strip (R402.2.11).
It helps as part of a closed crawl space: sealed vapor retarder on the ground, foam on the walls and rim joists, and drainage addressed first.
R-38 on the attic floor or R-20 of spray foam at the roof deck on the trade-off path.
NJ Spray Foam LLC installs attic & crawl space insulation across Dawson County and nearby areas. Send your address and photos to get started.